Corporate News
The role of low-temperature plasma hydrogen peroxide transfer window
Although there is no doubt that low-temperature plasma hydrogen peroxide transfer window has a sterilizing effect, in order to prevent frequent abnormalities and endanger normal startup due to errors in operation, it is necessary to master the proper operation of low-temperature plasma.Hydrogen peroxide sterilizerway.
1. Before starting, check the appearance of the low-temperature plasma hydrogen peroxide transfer window and whether there is any abnormality in the power plug. If there is any abnormality, you must first find out the cause before starting.2. Before starting, you need to check whether the negative pressure pump oil pump is at the normal liquid level line, whether there is any problem with the oil color, whether there is an oil pump in the air filter at the exhaust port, etc.; if the above situation occurs, no matter whether the oil pump is higher or lower than the normal liquid level line, no matter whether the oil color is clear or turbid, the oil pump needs to be replaced, and the oil mist separator must be cleaned or replaced.
3. If water or other evaporated substances enter the inner cavity of the pump, you can open the ballast valve for purification treatment; check whether there is water or stains in the air inlet air separator, and you can clean or replace it if necessary.
4. When replacing the oil pump, first run the mechanical pump for about three minutes and then add some oil. Then introduce about 100 ml of water into the oil inlet to clean the oil pump and clean it. After the waste oil is drained, refill the oil pump; generally filling it to between one-half and two-thirds of the oil mirror is enough.
5. If the plasma hydrogen peroxide sterilizer has not been used for more than three days, the system must be checked and rectified; and the side protection plate of the rotating shaft is removed, and the rotating shaft blade can be rotated by hand. If it is difficult to rotate no matter how much energy is used, the mechanical pump needs to be repaired.
6. Before sterilization, check whether the door sealing ring of the plasma hydrogen peroxide sterilizer is clean and deformed; check whether the filter at the air outlet of the sterilization chamber is blocked; check whether there are oil stains and residues in the indoor cavity; check whether the plasma sending head is clean and dry. Check whether there is too little hydrogen peroxide, which is not enough for one sterilization use.
Hydrogen peroxide transfer window is an air purification system used in clean rooms. It is suitable for short-term disinfection of equipment and air in clean rooms of different levels and non-clean areas of small and medium-sized banks, and effectively reduces the frequency of opening the clean room.
Hydrogen peroxide transfer window is integrated by a gasified hydrogen peroxide generator. The gasified hydrogen peroxide generator supplies hydrogen peroxide gas to the internal structure of the hydrogen peroxide transfer window to carry out microbial cleaning on the surface of the material to prevent the material from entering A and B level critical areas for contamination. Suitable for all types of clean and dry objects that must be transported during the sterility testing production process, including packaging products, equipment, raw materials, parts, environmental monitoring instruments, etc. Entering Class A and Class B heavily polluted areas.